Industrial Modbus TCP Gateway 1-Port (ATC-1300)

Product Details
Customization: Available
Task: Data Acquisition
Structure: Integration
Still deciding? Get samples of US$ 41.8/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (23)
  • Industrial Modbus TCP Gateway 1-Port (ATC-1300)
  • Industrial Modbus TCP Gateway 1-Port (ATC-1300)
  • Industrial Modbus TCP Gateway 1-Port (ATC-1300)
  • Industrial Modbus TCP Gateway 1-Port (ATC-1300)
  • Industrial Modbus TCP Gateway 1-Port (ATC-1300)
  • Industrial Modbus TCP Gateway 1-Port (ATC-1300)
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • May you have interesting
  • FAQ
Overview

Basic Info.

Model NO.
ATC-1300
Mathematical Model
Linear
Signal
Continuous
Function
Monitoring
Certification
RoHS, CE, CE, RoHS, FCC
Condition
New
Customized
Customized
Material
Plastic
Usage
Computer, Server, Gateway
Type
Wired
Support Network
Ethernet
Information Content
Data
Weight
0.45kg
Size
100 × 86 × 26 mm
Working Environment
-25 ~ 70°c (-13 ~ 158°f)
Power Supply
9~32VDC@1A
Data Rate
RS-232:1200 ~ 115200BPS; RS-422/485:1200 ~ 921600b
Warranty
2 Years
Install
DIN Rail
Package
Carton
Transport Package
Normal Paper Packing
Specification
Quality grade: CE
Trademark
ATC
Origin
China
HS Code
8543709990
Production Capacity
1, 000 Piece/Pieces / Week

Packaging & Delivery

Package Size
34.00cm * 28.00cm * 22.00cm
Package Gross Weight
10.000kg
Lead Time
3 days (1 - 100 Pieces)
6 days (101 - 300 Pieces)
8 days (301 - 500 Pieces)
To be negotiated ( > 500 Pieces)

Product Description

Product Description

Modbus TCP and Modbus RTU is an industry adopted communication protocol that is based on RTU protocols for various of applications; These two protocols are commonly used by a lot of equipment in the industry.Such as DCS, PLC, HMI, I/O module, Power meters, various sensors and measuring instruments. 
ATC-1300 support the standard Modbus protocol and is capable of converting the Modbus protocols between Modbus TCP (Master) to Modbus RTU 
(Slave). It's a simple and cost effective Modbus Gateway.

ATC-1300 which support three most commonly used serial communication interfaces, RS-232, RS-422 and RS-485. It also provides a web-based configuration UI, so the users can select the serial interface easily.

 

Industrial Modbus TCP Gateway 1-Port (ATC-1300)

 

Product Parameters

Serial Interface

Interface Type

RS-232/422/485 3 in 1

Data Rate

1200bps ~ 115200bps(RS-232),1200bps ~ 921600bps(RS-422/485)

Data Length

5,6,7,8 bits

Parity

Odd, Even, None

Stop Bits

1,1.5,2 bits

Flow Control

None, Hardware: Xon/Xoff

Connector

RS-232

DB-9 Male Connector

RS-485/422

6-pin Terminal Block

Serial Line Protection

600W for RS-232, RS-422/485

Network Interface

Interface Type

Ethernet 10/100Mbps (Auto-Sensing)

Connector

8-pin RJ-45

Isolation Protection

Built-in 1.5KV

Protocol

Modbus TCP/ Modbus RTU

Software

Network Protocols

ARP, TCP/IP, PING/ICMP, DHCP, BOOTP, Auto IP,TFTP, SNTP ,TELNET ,HTTP,  

DNS,SMTP, PPP, LCP, PAP, CHAP, IPCP, PPPoE. SSL/TLS,HTTPS

Configure Options

Web Page,Windows Utility

OS support

Windows95/98/ME/NT/2000/XP/2003/WIN7/WIN8/XP x64/2003 x64/WIN7 x64/WIN8 x64,

Linux real,TTY,UNIX

LED Indicators

LINK

Link Activity Indicator

ACT

Data Transmitting between Serial and Ethernet Indicator

TXD

Ethernet to transmit data to the serial port Indicator

RXD

Serial port to transmit data to Ethernet Indicator

PWR

Power indicator

Power Supply

9~24VDC@0.5A

Physical Characteristics

Installation

DIN-Rail Mounting (optional)

Housing

Iron (1mm)

Weight

0.5Kg

Dimensions

Without ears

100 × 67 × 26 mm(3.94 × 2.64 × 1.02 in)

With ears

100 × 86 × 26 mm(3.94 × 3.39 × 1.02 in)

Environmental Limits

Operating Temperature

-40 ~ 70°C (-13 ~ 158°F)

Storage Temperature

-40 ~ 85°C (-40 ~ 185°F)

Humidity

5% to 95%(non-condensing)

Standards and Certifications

RoHS, CE, FCC

 
 

Certifications

Industrial Modbus TCP Gateway 1-Port (ATC-1300)
Industrial Modbus TCP Gateway 1-Port (ATC-1300)
Industrial Modbus TCP Gateway 1-Port (ATC-1300)

May you have interesting

 
Industrial Modbus TCP Gateway 1-Port (ATC-1300)
Industrial Modbus TCP Gateway 1-Port (ATC-1300)
Industrial Modbus TCP Gateway 1-Port (ATC-1300)
                                                                         

FAQ

1.What about the delivery time?

We will shipping this goods to customer within 1-3 work days receive the payment. For customized products, We need to decide according to the customization requirements.

2.What is your delivery terms and payment terms?

We accept EXW, FOB, DAP, etc. You can choose the one which is the most convenient or cost effective for you.

3.After service and warranty?

We provide 2 year warranty, if you have any problems in the use of products, please contact to us.

4.Are you a trader or a manufacturer?

ATC is a manufacturing and trader. We have more than 20 years ofexperience in R&D and production.

5:What is the minimum order quantity(MOQ)?

We don't have MOQ for common product. MOQ can negotiate for customized products.

6. Does your company accept customize?

Yes, welcome to OEM and label according to your requirements.

7.Can I get a lower price if l order large quantities?

Yes, Cheaper prices with bigger size orders.

8.How to make payment?

We accept T/T ,Credit card and West Union

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier